Skip to content
implantswiss
Monoimplant · One-piece dental implants — smooth surface

Monoimplant Smooth: Smooth

Smooth-surface one-piece implants with an aggressive thread for immediate placement in extraction sockets and hard bone (D1–D2); Ø2.7 to Ø9.0, 8 to 35 mm.

Variants and codes
Monoimplant Smooth MS3514
Brand
Monoimplant — One-piece implant system
Family
Smooth
Type
One-piece dental implants — smooth surface
Category
Implants
Diameters
Ø2.7 · 3.5 · 4.0 · 4.5 · 5.5 · 7.0 · 9.0 mm
Lengths
8 – 35 mm
Indication
immediate placement; D1 – D2 bone
Features

Characteristics

Monoimplant types
  1. 01

    Smooth surface

    No place for bacterial colonisation; better oral hygiene where bone resorption is likely after surgery.

  2. 02

    Sharp self-tapping thread

    Slices the bone instead of compressing it; cortical engagement at crest and apex.

  3. 03

    Two abutment sizes

    Normal and large abutment; trimming for prosthetic ease.

  4. 04

    One-piece body

    No abutment screw: no screw loosening, fracture or micro-movement at an implant–abutment interface.

  5. 05

    Bicortical anchorage

    Fixated between entry and exit cortical plates for primary stability that does not depend on trabecular bone.

  6. 06

    Titanium grade 5

    Biocompatible grade 5 titanium; abutments can be trimmed and are compatible with welding (syncrystallization).

Variants

Codes

Monoimplant Smooth MS3514
Smooth (MS)
LengthØ2.7Ø3.5Ø4.0Ø4.5Ø5.5Ø7.0Ø9.0
8 mm———MS4508MS5508MS7008MS9008
10 mmMS2710MS3510MS4010MS4510MS5510MS7010MS9010
12 mmMS2712MS3512MS4012MS4512MS5512MS7012MS9012
14 mmMS2714MS3514MS4014MS4514MS5514MS7014MS9014
17 mmMS2717MS3517MS4017MS4517MS5517——
20 mmMS2720MS3520MS4020MS4520MS5520——
23 mmMS2723MS3523MS4023MS4523MS5523——
26 mmMS2726MS3526MS4026MS4526———
29 mmMS2729MS3529MS4029MS4529———
32 mm—MS3532MS4032————
35 mm—MS3535MS4035————

Large-abutment versions carry the suffix -LAb (Ø3.5 to Ø9.0). Ø2.7 is not intended as a single implant; in a thin jawbone at least 12 implants per jaw are required (catalogue).

One-piece implants restored in the mandible
Connection

Prosthetic head

The abutment is part of the implant body (normal or large). Impressions use the MIC transfer, burn-out cap and lab analog (MIC-LAb for the large abutment); scan body MSB / MSB-LAb and digital analog MDLA / MDLA-LAb for the digital workflow.

Compatible with

Documented compatibility

Only combinations stated in the product documentation are listed here; related products of the same brand are not assumed to be compatible.

All brands →